Background: Atrial fibrillation (AF) is a major cause of stroke in older people. Exacerbated by age and co-morbidities, residents of care homes are more likely to develop AF and less likely to receive oral anticoagulants.

Aim: To determine the prevalence of AF using the design and methodology of the Pharmacists Detecting Atrial Fibrillation (PDAF) study in a care home setting.

Method: A cross-sectional AF screening pilot study within four UK care homes, three residential and one residential/nursing. Screening followed the original PDAF protocol: a manual pulse check, followed by a single-Lead ECG (SLECG, AliveCor Kardia Mobile (KMD)) delivered by a pharmacist. All recorded SLECG were reviewed by a cardiologist and any residents requiring follow-up investigations were referred to their general practitioner.

Results: Fifty-three of 112 care home residents participated. From 52 SLECGs recorded, the cardiologist interpreted 13.5% (7/52) as having possible AF of which 9.6% (5/52) were previously unknown. One resident with previously unknown AF received anticoagulation.

Conclusion: This study has shown a need for AF screening in care homes and that elements of the PDAF screening protocol are transferable in this setting. Early diagnosis and treatment of AF are essential to reduce the risk of stroke in this population.