TY - JOUR
T1 - Survival of patients with cardiac implantable electronic device infections after transvenous lead extraction
AU - Ulman, Mateusz
AU - Boczar, Krzysztof
AU - Karkowski, Grzegorz
AU - Holcman, Katarzyna
AU - Dębski, Maciej
AU - Kostkiewicz, Magdalena
AU - Lelakowski, Jacek
AU - Ząbek, Andrzej
N1 - Publisher Copyright:
© by the Author(s), 2026.
PY - 2026
Y1 - 2026
N2 - Background: Cardiac implantable electronic device (CIED) infections, particularly CIED-associated infective endocarditis (CIED-associated IE), are associated with a high 1-year mortality rate of 14%–35%, reduced quality of life, and increased burden on the healthcare system. Aims: In this prospective, single-center, high-volume referral study, we aimed to analyze and compare 3 groups of patients who underwent transvenous lead extraction (TLE): patients with CIED-associated IE, patients with pocket infection (PI), and both. Methods: This study included all consecutive patients with CIEDs who underwent TLE due to device-related infection at a tertiary referral hospital between 2011 and 2023. Patients were divided into 3 groups (CIED-associated IE, PI, and both indications) based on the modified Duke criteria. Results: A total of 253 consecutive patients underwent TLE. Of these, 135 (53%) were treated for PI, 90 (36%) for CIED-associated IE, and 28 (11%) for both indications. Almost all procedures (97%) were completed without complications. Patients with CIED-associated IE had significantly higher mortality than patients in the CIED-associated IE + PI group, and patients in the PI group had the lowest mortality. One-year, 2-year, and 5-year overall survival rates in the CIED-associated IE group were 61%, 49%, and 32%, respectively, compared with 77%, 73%, and 56% in the CIED-associated IE + PI group and 90%, 86%, and 67% in the PI group (P <0.001). Conclusions: Patients with CIED-associated IE had almost 4-fold higher 1-year mortality compared to those with PI. Patients with CIED-associated IE and PI had about 2-fold higher 1-year mortality compared to those with PI.
AB - Background: Cardiac implantable electronic device (CIED) infections, particularly CIED-associated infective endocarditis (CIED-associated IE), are associated with a high 1-year mortality rate of 14%–35%, reduced quality of life, and increased burden on the healthcare system. Aims: In this prospective, single-center, high-volume referral study, we aimed to analyze and compare 3 groups of patients who underwent transvenous lead extraction (TLE): patients with CIED-associated IE, patients with pocket infection (PI), and both. Methods: This study included all consecutive patients with CIEDs who underwent TLE due to device-related infection at a tertiary referral hospital between 2011 and 2023. Patients were divided into 3 groups (CIED-associated IE, PI, and both indications) based on the modified Duke criteria. Results: A total of 253 consecutive patients underwent TLE. Of these, 135 (53%) were treated for PI, 90 (36%) for CIED-associated IE, and 28 (11%) for both indications. Almost all procedures (97%) were completed without complications. Patients with CIED-associated IE had significantly higher mortality than patients in the CIED-associated IE + PI group, and patients in the PI group had the lowest mortality. One-year, 2-year, and 5-year overall survival rates in the CIED-associated IE group were 61%, 49%, and 32%, respectively, compared with 77%, 73%, and 56% in the CIED-associated IE + PI group and 90%, 86%, and 67% in the PI group (P <0.001). Conclusions: Patients with CIED-associated IE had almost 4-fold higher 1-year mortality compared to those with PI. Patients with CIED-associated IE and PI had about 2-fold higher 1-year mortality compared to those with PI.
KW - cardiac implantable electronic devices
KW - CIED-associated infective endocarditis
KW - transvenous lead extraction
UR - https://www.scopus.com/pages/publications/105031933224
U2 - 10.33963/v.phj.111009
DO - 10.33963/v.phj.111009
M3 - Article
C2 - 41631507
AN - SCOPUS:105031933224
SN - 0022-9032
VL - 84
SP - 231
EP - 237
JO - Kardiologia Polska
JF - Kardiologia Polska
IS - 2
ER -